Skip to content Skip to navigation

SSFF Instrument Schedules and Configurations

 

 

 

Services

Consultations    
Consultation Schedule Consultation appointments provide an opportunity to plan experiments, design staining panels, analyze data, learn software, or troubleshoot results.  Select a time on the schedule and a staff member will send a Zoom meeting link for the appointment.

 

Analyzers - Main Campus

  • 30min minimum appointment

  • All operator and instrument time will be charged in full if cancelled within the 24hour of appointment start time
Name Model Schedule Lasers Detectors Plate Reader

AURORA

Aurora Aurora Schedule Blue, Violet, UV, Yellow, Red 30+ spectral Yes
LSRII LSRII LSRll Schedule Blue, Violet, Green, Red 8-Violet, 2-Blue, 5-Green, and 3-Red No
LSRII.UV LSRII LSRll.UV Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red No

QUANTEON*

Quanteon Quanteon Schedule Blue, Violet, Yellow, Red 7-Blue, 8-Violet, 6-Yellow, 4-Red Yes
PENTEON* Penteon Penteon Schedule Blue, UV, Violet, Yellow, Red 6-Blue, 7-UV, 7-Violet, 6-Yellow, 4-Red Yes

SYMPHONY

Symphony Symphony Schedule Blue, UV, Violet, Yellow, Red 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red No
SYMPHONY 2 Symphony Symphony 2 Schedule Blue, UV, Violet, Yellow, Red 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red No

*To help keep costs down, Quanteon and Penteon instruments off a Sample Drop-off operator option; when selecting this option, we only charge the time for setup/cleanup/data management.  So for single experiment setup <8 colors we charge 30min operator; for experiments with >7 colors, we charge one hour; the sample drop-off form is required; includes a basic setup; basic gates - extensive sample name labels, etc can be entered by the user, if preferred.  Users are NOT required to stay  - but must verify the operator has their form AND has the chance to ask clarifying questions.  Samples dropped off without speaking to a staff member, or dropped off more than 30min after the appt start time will not be run without prior arrangement.  User wanting staff present for the entire time should select either Training or a specific operator NOT Sample Drop off operator.

Sorters - Main Campus

  • 1 hour minimum sort appointment time
  • All operator and instrument time will be charged in full if cancelled within 48 hour of appointment start time
  • Clinical sorters are: AIDA, PICI, FALSTAFF, DON CARLO, FUSION, MIKADO, CARMEN 
  • Clinical samples cannot be run on VERDI sorter
Name Model Schedule Lasers Detectors Cloner
AIDA FACSAria II Aida Schedule Blue, Violet, Red, Yellow

5-Violet, 2-Blue, 4-Yellow, and 3-Red

Yes
FALSTAFF FACSAria II Falstaff Schedule Blue, UV, Violet, Green, Red 2-UV, 5-Violet, 2-Blue, 5-Green, and 3-Red No
MIKADO Sony SH800 Mikado Schedule Blue, Violet, Yellow Blue/Violet/Yellow colinear - 6 Yes, best for 384-well plate
MARTHA Sony SH800 Martha Schedule Blue, Red, Violet, Yellow Blue/Red/Violet/Yellow colinear - 6 Yes - NO 384 well plates 
GEORGE Sony SH800

George Schedule

Blue, Red, Violet, Yellow Blue/Red/Violet/Yellow colinear - 6 Yes - NO 384 well plates
PICI FACSAria Fusion PICI Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red Yes
VERDI

FACSAria II

Verdi Schedule Blue, Yellow, Red 2-Blue, 3-Yellow, and 3-Red laser Yes

S8

BD FACSDiscover S8 S8 Schedule  Blue, UV, Violet, Yellow/Green, Red, Image Blue spectral, 3-Image Blue Yes
AURORA - CS Auorora - CS Aurora - CS Schedule Blue, Violet, UV, Yellow, Red 30+ spectral Yes 

 

PAGE MILL SATELLITE

  • 30min minimum appointment (analyzer)
  • 1 hour minimum appointment (sorter)
  • All operator and instrument time will be charged in full if cancelled within 24 hour of appointment start time
  • Call 650-723-6959 for day-time phone support or email facs-inquiries@lists.stanford.edu to book operator-assisted appointments
Name Model Schedule Lasers Detectors PLATE READER/Cloner
FORTESSA BD LSRFortessa Cell Analyzer Fortessa Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red no
COSTELLO FACSAria Fusion - Sorter Costello Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red Cloner

 

Last modified: 
Thu, 4 Jun 2026 at 9:37 am