Skip to content Skip to navigation

SSFF Instrument Schedules and Configurations

 

 

 

Services

Consultations    
Consultation Schedule Consultation appointments provide an opportunity to plan experiments, design staining panels, analyze data, learn software, or troubleshoot results.  Select a time on the schedule and a staff member will send a Zoom meeting link for the appointment.

 

Analyzers - Main Campus

  • 30min minimum appointment

  • All operator and instrument time will be charged in full if cancelled within the 24hour of appointment start time
Name Model Schedule Lasers Detectors Plate Reader

AURORA

Aurora Aurora Schedule Blue, Violet, UV, Yellow, Red 30+ spectral Yes
Cyrano CyTOF2 Cyrano Schedule Argon plasma 50+ channels No
LSRII LSRII LSRll Schedule Blue, Violet, Green, Red 8-Violet, 2-Blue, 5-Green, and 3-Red Yes
LSRII.2 LSRII

LSRll.2 Schedule

Blue, UV, Violet, Green, Red 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red Yes
LSRII.UV LSRII LSRll.UV Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red Yes

QUANTEON

Quanteon Quanteon Schedule Blue, Violet, Yellow, Red 7-Blue, 8-Violet, 6-Yellow, 4-Red Yes
PENTEON Penteon Penteon Schedule Blue, UV, Violet, Yellow, Red 6-Blue, 7-UV, 7-Violet, 6-Yellow, 4-Red Yes

SYMPHONY

Symphony Symphony Schedule Blue, UV, Violet, Yellow, Red 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red Yes
SYMPHONY 2 Symphony Symphony 2 Schedule Blue, UV, Violet, Yellow, Red 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red Yes

 

Sorters - Main Campus

  • 1 hour minimum sort appointment time
  • All operator and instrument time will be charged in full if cancelled within 48 hour of appointment start time
  • Clinical sorters are: AIDA, PICI, FALSTAFF, DON CARLO, FUSION, MIKADO, CARMEN 
  • Clinical samples cannot be run on VERDI sorter
Name Model Schedule Lasers Detectors Cloner
AIDA FACSAria II Aida Schedule Blue, Violet, Red, Yellow

5-Violet, 2-Blue, 4-Yellow, and 3-Red

Yes
FUSION FACSAria Fusion Fusion Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red Yes
CARMEN Influx Carmen Schedule Blue, UV, Violet, NearBlue, Yellow, Red 2-UV, 4-Violet, 2-NearBlue, 2-Blue+ FSC PMT, 4-Yellow, and 3-Red Yes, best for 384-well plate
FALSTAFF FACSAria II Falstaff Schedule Blue, UV, Violet, Green, Red 2-UV, 5-Violet, 2-Blue, 5-Green, and 3-Red Yes
MIKADO Sony SH800 Mikado Schedule Blue, Violet, Yellow Blue/Violet/Yellow colinear - 6 Yes, best for 384-well plate
PICI FACSAria Fusion PICI Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red Yes
DON CARLO FACSymphony S6 Sorter DON CARLO Schedule Blue, UV, Violet, Yellow-Green, Red 9-Blue, 10-UV, 14-Violet, 9-Yellow/Green, 6-Red Yes
VERDI FACSAria II Verdi Schedule Blue, Yellow, Red 2-Blue, 3-Yellow, and 3-Red laser Yes

 

PAGE MILL SATELLITE

  • 30min minimum appointment (analyzer)
  • 1 hour minimum appointment (sorter)
  • All operator and instrument time will be charged in full if cancelled within 24 hour of appointment start time
  • Call 650-723-6959 for day-time phone support or email facs-inquiries@lists.stanford.edu to book operator-assisted appointments
Name Model Schedule Lasers Detectors PLATE READER/Cloner
FORTESSA BD LSRFortessa Cell Analyzer Fortessa Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red no
COSTELLO FACSAria Fusion - Sorter Costello Schedule Blue, UV, Violet, Yellow, Red 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red Cloner

 

Last modified: 
Mon, 17 Jun 2024 at 4:57 pm