Consultations | |
---|---|
Consultation Schedule | Consultation appointments provide an opportunity to plan experiments, design staining panels, analyze data, learn software, or troubleshoot results. Select a time on the schedule and a staff member will send a Zoom meeting link for the appointment. |
Name | Model | Schedule | Lasers | Detectors | Plate Reader |
---|---|---|---|---|---|
AURORA |
Aurora | Aurora Schedule | Blue, Violet, UV, Yellow, Red | 30+ spectral | Yes |
Cyrano | CyTOF2 | Cyrano Schedule | Argon plasma | 50+ channels | No |
LSRII | LSRII | LSRll Schedule | Blue, Violet, Green, Red | 8-Violet, 2-Blue, 5-Green, and 3-Red | Yes |
LSRII.2 | LSRII | Blue, UV, Violet, Green, Red | 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red | Yes | |
LSRII.UV | LSRII | LSRll.UV Schedule | Blue, UV, Violet, Yellow, Red | 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red | Yes |
Quanteon | Quanteon Schedule | Blue, Violet, Yellow, Red | 7-Blue, 8-Violet, 6-Yellow, 4-Red | Yes | |
PENTEON | Penteon | Penteon Schedule | Blue, UV, Violet, Yellow, Red | 6-Blue, 7-UV, 7-Violet, 6-Yellow, 4-Red | Yes |
Symphony | Symphony Schedule | Blue, UV, Violet, Yellow, Red | 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red | Yes | |
SYMPHONY 2 | Symphony | Symphony 2 Schedule | Blue, UV, Violet, Yellow, Red | 7-UV, 8-Violet, 6-Blue, 5-Yellow, and 3-Red | Yes |
Name | Model | Schedule | Lasers | Detectors | Cloner |
---|---|---|---|---|---|
AIDA | FACSAria II | Aida Schedule | Blue, Violet, Red, Yellow |
5-Violet, 2-Blue, 4-Yellow, and 3-Red |
Yes |
FUSION | FACSAria Fusion | Fusion Schedule | Blue, UV, Violet, Yellow, Red | 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red | Yes |
CARMEN | Influx | Carmen Schedule | Blue, UV, Violet, NearBlue, Yellow, Red | 2-UV, 4-Violet, 2-NearBlue, 2-Blue+ FSC PMT, 4-Yellow, and 3-Red | Yes, best for 384-well plate |
FALSTAFF | FACSAria II | Falstaff Schedule | Blue, UV, Violet, Green, Red | 2-UV, 5-Violet, 2-Blue, 5-Green, and 3-Red | Yes |
MIKADO | Sony SH800 | Mikado Schedule | Blue, Violet, Yellow | Blue/Violet/Yellow colinear - 6 | Yes, best for 384-well plate |
PICI | FACSAria Fusion | PICI Schedule | Blue, UV, Violet, Yellow, Red | 3-UV, 6-Violet, 2-Blue, 4-Green, and 3-Red | Yes |
DON CARLO | FACSymphony S6 Sorter | DON CARLO Schedule | Blue, UV, Violet, Yellow-Green, Red | 9-Blue, 10-UV, 14-Violet, 9-Yellow/Green, 6-Red | Yes |
VERDI | FACSAria II | Verdi Schedule | Blue, Yellow, Red | 2-Blue, 3-Yellow, and 3-Red laser | Yes |
Name | Model | Schedule | Lasers | Detectors | PLATE READER/Cloner |
---|---|---|---|---|---|
FORTESSA | BD LSRFortessa Cell Analyzer | Fortessa Schedule | Blue, UV, Violet, Yellow, Red | 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red | no |
COSTELLO | FACSAria Fusion - Sorter | Costello Schedule | Blue, UV, Violet, Yellow, Red | 3-UV, 6-Violet, 2-Blue, 4-Yellow, and 3-Red | Cloner |